Our System


Engineered for Strength.
Designed for Simplicity.

The Blocks

Close-up of white Styrofoam packaging inserts with circular and rectangular cutouts, arranged in a grid pattern.

250mm Profile


Heavy Retaining, Basements & Multi-Storey

  • Dimensions: 300mm (H) × 1250mm (L)

  • Concrete Yield: 1 m³ fills approx. 8 m² of wall area

  • Thermal & Acoustic: R3.81 | STC 50 acoustic rating

  • Best Used For: Heavy structural retaining walls, earth-sheltered and underground homes, deep basements, and multi-storey commercial construction demanding maximum thermal mass and load capacity.

White plastic film reel storage container with a circular cutout and film strips, used to hold and organize film reels.

200mm Profile


Standard External Walls & Earth-Retaining

  • Dimensions: 300mm (H) × 1200mm (L)

  • Concrete Yield: 1 m³ fills approx. 11 m² of wall area

  • Thermal & Acoustic: R3.1 | STC 48 acoustic rating

  • Best Used For: The go-to standard for external residential walls up to three storeys, integrated retaining walls, wine cellars, and bushfire-prone building envelopes.

White foam packaging with interlocking edges and a cut-out handle

150mm Profile


Single-Storey External & Load-Bearing Walls

  • Dimensions: 300mm (H) × 1200mm (L)

  • Concrete Yield: 1 m³ fills approx. 15 m² of wall area

  • Thermal & Acoustic: R2.3

  • Best Used For: External walls on single-storey homes, internal structural spine walls, and garage perimeter walls where space efficiency and solid concrete strength are required.

Two white foam corner protectors with a slot and a semi-circular cutout, used for padding and protecting corners in packaging or shipping.

125mm Profile


Internal & Partition Walls

  • Dimensions: 300mm (H) × 1250mm (L)

  • Concrete Yield: 1 m³ fills approx. 20 m² of wall area

  • Thermal & Acoustic: R2.0 | 43 dB sound rating

  • Best Used For: Internal dividing walls, party walls, and load-bearing partitions (when reinforced to engineering specifications). Eliminates room-to-room noise without taking up excess floor space.

The Reinforced Concrete
Core is the Strength. The Polystyrene is the Unrivalled Thermal Protection.

Various concrete blocks and molds stacked against a white wall, with a sign indicating one block is a 200mm Thermacell core.
Construction site with a partially built white wall frame and sandy ground

Structural Lintels

Thermacell makes framing window and door openings simple by creating monolithic, reinforced concrete lintels directly inside the block run—eliminating the need for separate steel angles or heavy precast beams.

  • Flexible Window & Door Head Heights: The 300 Series blocks feature an engineered deep-flow concrete channel across the base, allowing standard blocks or 150mm lintel blocks to bridge openings effortlessly. This gives you total flexibility to set clean head heights at standard residential levels, including 2100mm, 2250mm, or 2400mm.

  • Continuous Steel Reinforcement: Before pouring, suspend your specified reinforcing steel centrally within the lintel cavity. Ensure all rebar extends at least 500mm past each side of the opening into the adjacent wall core to tie the structural load cleanly into the surrounding building envelope.

  • Temporary Underside Propping: Support the underside of the lintel blocks with a straight timber soleplate and vertical props. This holds your openings dead level and carries the wet concrete load securely until the pour cures.

Person in a red jacket holds a white foam block in an outdoor setting with stacked foam blocks and a truck in the background.

Pre-Formed Window Sills

Thermacell manufactures dedicated EPS window sill profiles in 2.5m lengths, matched to suit both 150mm and 200mm block systems.

  • Simple Post-Pour Installation: Once your concrete pour is complete and leveled, bed the 80mm-thick sill profile directly across the block opening. The downward weight of your window sub-frame holds the sill securely in position.

  • Allowance for Height: Remember to allow for the 80mm sill thickness when framing and setting out your rough opening heights.

  • Durable Rendered Finish: Plasterers wrap and bed alkali-resistant fibreglass mesh into the acrylic render across the protruding sill profile, creating a sharp, watertight, and impact-resistant external finish.

Downloads

Cyclonic Engineering 300mm Series.pdf

CSIRO Appraisal.pdf

Engineering 300mm Block Series.pdf

BAL 29 Rated.pdf

Warrington Fire Research Report.pdf

Mag Board.pdf

An elderly man is working with a large piece of white foam insulation that is burning or melting from a heat source directed at it. The man is outdoors, wearing glasses and a green shirt.
Close-up of a painted wooden fence with a concrete foundation at the bottom.

Certified & Approved to
BAL-29

Conventional brick-veneer and timber-framed homes often fail catastrophically in a bushfire—extreme radiant heat causes mortar beds to crack, walls to buckle, and exposed internal timber framing to ignite. Thermacell eliminates this vulnerability by forming a continuous, steel-reinforced solid concrete core that will not burn, buckle, or collapse under severe radiant heat loads.

Paired with the Dulux AcraTex coating system, Thermacell is formally accredited to BAL-29 (Bushfire Attack Level 29) under AS 1530.8.1: 2007 following rigorous independent testing by Exova Warringtonfire.

  • Flame-Retardant EPS Formwork: The expanded polystyrene contains a built-in flame retardant that shrinks away from extreme heat without igniting or fuelling flame spread.

  • Multi-Layer Defensive Barrier: An external Dulux AcraTex acrylic render with embedded alkali-resistant fibreglass mesh forms the primary radiant heat and ember shield, backed internally by plasterboard linings or non-combustible boards.

  • Structural Core Integrity:CSIRO and independent testing confirm the monolithic concrete core retains 100% of its load-bearing structural capacity during extreme fire events.

  • Planning & Council Compliance:Thermacell reliably satisfies stringent local council regulations and Australian bushfire construction standards (AS 3959), giving owner-builders and architects total compliance confidence in high-risk zones.

Aerial view of a neighborhood severely damaged by a fire, with charred and collapsed buildings, burned trees, and a mostly destroyed landscape.

Hurrican & Cyclone Resilience

Facing 240 km/h winds and a massive storm surge, an ICF home’s solid, steel-reinforced concrete envelope have held their structural ground without cracking or shifting in extreme conditions, allowing the owners to repair the roof finishes and move straight back in.

  • Monolithic Lateral Strength: Unlike timber frames or brick-veneer walls that rip apart under extreme wind shear and uplift, Thermacell’s solid reinforced concrete core acts as a single, continuous structural unit.

  • Engineered for High-Wind & Cyclonic Zones: Thermacell complies directly with AS 3600 (Concrete Structures) and AS 4055 (Wind Loads for Housing), providing the certified mass and tie-down capacity required for Australia's most severe cyclonic regions.

  • Impact & Debris Protection: High-velocity airborne debris that penetrates conventional cladding cannot breach a solid reinforced concrete core, safeguarding your family and keeping the building envelope intact.

Whatever You’re BuildIng,
Build It with Total Confidence.

Stack, Lock, and Pour

Common Questions

Contact Us

Interested in working together? Fill out some info and we will be in touch shortly.