Do I need steel reinforcing for the walls?

For non-cyclonic areas the only steel required in the walls is a single Y-12 reinforcing bar, to be placed either side of windows and doors in the outside walls.

Windows up to 2m in width require a Y-12 bar fitted across the top of the window to form a lintel. Windows over 2m may require a Y-16 bar.

It is recommended that a continuous Y-12 bar be placed in the top course of the exterior walls.

If 125mm Thermacell blocks are used for internal walls, no reinforcing is required unless these walls are required to be load bearing.

Further information on steel reinforcing can be obtained from the Thermacell design manual or by contacting Thermacell (Australia) Pty Ltd.

AddThis Social Bookmark Button

Contact Us

Head Office
P.O Box 447
Somerville
Victoria, 3912
Australia
Phone: (03) 5977 7996
Mobile: 0414 664 500

Email Us Today

Recommended Builders

Over the nearly thirty years Thermacell has been in business, we have worked with several different builders, construction companies and tradesmen. We have compiled a list of just some of these builders and tradesmen Read More

IMPORTANT INFORMATION

There is a company in Perth W.A. calling itself Thermacell I.C.F. International. We wish to advise that this Company has no affiliation with Thermacell Australia, and that we are not responsible for any of their marketing activities. We advise that any enquiries for dealerships or product sales must be made through our head office in Victoria where it has been since 1985